JCB logo
Accuri Cytometers
  Home | Help | Feedback | Subscriptions | Archive | Search | Table of Contents

This Article
Right arrow Full Text (PDF, 1566K)
Right arrow Alert me when this article is cited
Services
Right arrow Email this article
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new content in the JCB
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via CrossRef
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Williams, R. C.
Right arrow Articles by Kallman, F.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Williams, R. C.
Right arrow Articles by Kallman, F.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?
J. Biophys. and Biochem. Cytol., Vol 1, 301-314, Copyright © 1955 by Rockefeller University Press

ARTICLE

INTERPRETATIONS OF ELECTRON MICROGRAPHS OF SINGLE AND SERIAL SECTIONS

Robley C. Williams Ph.D.1 and Frances Kallman Ph.D.1

1 (From the Virus Laboratory, University of California, Berkeley)

A method of securing serial sections for electron microscopy is described. Serial sections present certain anomalies of interpretation of a nature such that a complete and detailed three-dimensional reconstruction of the sectioned tissue cannot be made. These anomalies are discussed, as well as those which have been encountered in the interpretation of single sections. Observations of the following kinds have been made in an attempt to elucidate the interpretation of single and serial sections: differing methods of mounting adjacent sections, observation of the same section by high-angle stereoscopy, and examination of sections which have been shadowed prior to and subsequent to electron microscopy.

It is found that the appearance of sections is independent of the choice of side to be placed against the formvar films. Stereoscopy shows that the appearance of fine structures is strongly dependent upon the direction of the penetrating electron beam with respect to the plane of the structures. Stereoscopy, combined with shadowing, shows quantitatively that extensive sublimation of polymer occurs upon normal exposure in the electron microscope. Observation of sections shadowed prior to electron microscopy indicates that varying amounts of material are removed between sections by the action of microtomy; i.e., it is probable that the sum of the thicknesses of several serial sections is considerably less than the total thickness of material removed from the block. It is believed that this effect, combined with the effect of sublimation, aids in explaining the failure of adjacent sections to exhibit continuity in their detailed structures.

Submitted on April 15, 1955


Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?




  Home | Help | Feedback | Subscriptions | Archive | Search | Table of Contents