JCB logo
Sign up for e-mail content alerts
  Home | Help | Feedback | Subscriptions | Archive | Search | Table of Contents

This Article
Right arrow PDF (Full Text)
Right arrow Alert me when this article is cited
Services
Right arrow Email this article
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new content in the JCB
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via CrossRef
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Caro, L. G.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Caro, L. G.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?
The Journal of Cell Biology, Vol 15, 189-199, Copyright © 1962 by Rockefeller University Press

ARTICLE

HIGH-RESOLUTION AUTORADIOGAPHY : II. The Problem of Resolution



Lucien G. Caro Ph.D1

1 From The Rockefeller Institute

The resolution obtainable in electron microscopic autoradiographs, using a photographic emulsion consisting of a monolayer of silver bromide crystals, was investigated theoretically and experimentally. The expected distribution of exposed crystals around a point source was calculated from the geometry of the preparation and from the range distribution of the beta particles emitted by tritium. From such a distribution an autoradiographic resolution of the order of 1000 A can be predicted. From the point source distribution, the expected distribution of grains around bacteriophages labeled with tritium was calculated. This distribution was also measured experimentally in electron microscopic autoradiographs of bacteriophages T-2 labeled with thymidine-H3. The two distributions agreed closely. It was also verified, using the nuclear region in thin cross-sections of Bacillus subtilis labeled with thymidine-H3, that resolutions of the same order were obtained for extended sources. It was concluded that an autoradiographic resolution of 1000 A could be achieved with a presently available commercial emulsion, although emulsions with finer grains might be desirable in some circumstances.

Submitted on June 14, 1962


Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?


This article has been cited by other articles:



  Home | Help | Feedback | Subscriptions | Archive | Search | Table of Contents